Fluid Responsiveness After CArdiac Surgery (FRACAS): A Prospective Observational Study Using Peripheral Near-Infrared
Ethan Butler1, John Nguyen1, Sajeev Mahendran1
1Faculty of Medicine, University of New South Wales, Sydney, Australia.
Objectives:
To describe tissue oxygen saturation (StO2) in response to a vascular occlusion test using thenar eminence and forearm near-infrared spectroscopy (NIRS) and the association with volume responsiveness after cardiac surgery.
Design:
Single-center, prospective, observational cohort study.
Setting:
Cardiothoracic intensive care unit.
Participants:
Seventy-six post-cardiac surgical adults.
Interventions:
Immediately before and 10 minutes after a 250-to-500 mL fluid bolus, StO2 was measured in response to a vascular occlusion test to calculate tissue deoxygenation (Rdes) and reoxygenation (Rres) rates. Concurrently, systemic hemodynamic, metabolic, and blood gas variables were collected.
Measurements And Main Results:
A total of 203 boluses were captured using thenar NIRS and 141 boluses using forearm NIRS. Approximately 25% of boluses increased cardiac output by ≥15% (volume responders). Thenar and forearm Rdes decreased in responders, but increased (thenar) or remained unchanged (forearm) in nonresponders. A logistic regression model of the association among StO2, Rdes and Rres, and volume responsiveness was significant for thenar measurements (p = 0.001) with an area under the receiver operating characteristic of 0.69 (95% confidence interval: 0.62-0.75). It also was significant (p = 0.02) for forearm measurements, with an area under the receiver operating characteristic of 0.71 (0.62-0.79). Rdes was an independent variable in both instances (odds ratio 0.31 [0.14-0.69], thenar; odds ratio 0.60 [0.45-0.80], forearm). Thenar and forearm NIRS variables were correlated poorly with cardiac output, stroke volume, systemic oxygen delivery and consumption index, mixed venous, and central venous oxygen saturation (Spearman׳s coefficients, r = 0.17-0.46, p < 0.002).
Conclusion:
In post-cardiac surgical patients, thenar and forearm NIRS variables were associated with volume responsiveness although not achieving precision necessary for clinical management.