Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and
Evan Levine1, Kathryn Stevens1, Christopher Beaulieu1
1Department of Electrical Engineering and Radiology, Stanford University, Stanford, California, USA.
Purpose:
To enable highly accelerated distortion-free MRI near metal by separating on- and off-resonance to exploit the redundancy of slice-phase encoding for the dominant on-resonance component.
Methods:
Multispectral MRI techniques resolve off-resonance distortions by a combination of limited excitation bins and additional encoding. Inspired by robust principal component analysis, a novel compact representation of multispectral images as a sum of rank-one and sparse matrices corresponding to on- and off-resonance respectively is described. This representation is used in a calibration-free and model-free reconstruction for data with an undersampling pattern that varies between bins. Retrospective undersampling was used to compare the proposed reconstruction and bin-by-bin compressed sensing. Hip images were acquired in eight patients with standard and prospectively undersampled three-dimensional multispectral imaging, and image quality was evaluated by two radiologists on a 5-point scale.
Results:
Experiments with retrospective undersampling showed that the enhanced sparsity afforded by the separation greatly reduces reconstruction errors and artifacts. Images from prospectively undersampled multispectral imaging offered 2.6-3.4-fold (18-24-fold overall) acceleration compared to standard multispectral imaging with parallel imaging and partial-Fourier acceleration with equivalence in all qualitative assessments within a tolerance of one point (P < 0.004).
Conclusion:
Three-dimensional multispectral imaging can be highly accelerated by varying undersampling between bins and separating on- and off-resonance. Magn Reson Med 79:1495-1505, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Magnetic Resonance Imaging
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
NMR Spectrometers: Resolution and Error Correction