137Cs transmission imaging and segmented attenuation corrections in a small animal PET scanner
Ying-Hwey Nai1,2, Takayuki Ose3, Miho Shidahara4
1Division of Radiation Informatics for Medical Imaging, Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan.
Abstract:
Attenuation correction (AC) is required for accurate quantitative evaluation of small animal PET data. Our objective was to compare three AC methods in the small animal Clairvivo-PET scanner. The three AC methods involve applying attenuation coefficient maps generated by simulating a cylindrical map (SAC), segmenting the emission data (ESAC), and segmenting the transmission data (TSAC), imaged using a 137Cs single-photon source. Investigation was carried out using a 65 mm uniform cylinder and an NEMA NU4 2008 mouse phantom, filled with water or tungsten liquid, to mimic bone. Evaluation was carried out using the difference of the segmented map volume from the known cylindrical phantom volume, the recovery of the radioactivity concentration, and the line profiles. The optimal transmission scan time for achieving accurate AC using TSAC was determined using 5, 10, 15, 20, and 25 min transmission scan time. The effects of scatter correction and reconstruction algorithms on ESAC were investigated. SAC showed the best performance but was unable to correct for different tissues and the scanner bed, and faced difficulty with correct positioning of the attenuation coefficient map. ESAC was affected by scatter correction and reconstruction algorithm, and may result in poor boundary delineation, and hence was unreliable. TSAC showed reasonable performance but required further optimization of the default segmentation setting. A minimum transmission scan time of 20 min is recommended for Clairvivo-PET using 137Cs source to ensure that sufficient transmission counts are obtained to generate accurate attenuation coefficient map.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...