Related Experiment Video
Updated: Feb 26, 2026

Imaging and Quantification of the Hepatic Vasculature of Mice Using Ultrafast Doppler Ultrasound
Published on: July 19, 2024
Automatic Identification of the Optimal Reference Frame for Segmentation and Quantification of Focal Liver Lesions in
Spyridon Bakas1, Dimitrios Makris2, Gordon J A Hunter2
1Digital Information Research Centre (DIRC), School of Computer Science & Mathematics, Faculty of Science, Engineering and Computing (SEC), Kingston University, Penrhyn Road, Kingston-Upon-Thames, London, United Kingdom; Center for Biomedical Image Computing and Analytics (CBICA), Perelman School of Medicine, University of Pennsylvania, Richards Medical Research Laboratories, Philadelphia, PA, USA.
Abstract:
Post-examination interpretation of contrast-enhanced ultrasound (CEUS) cineloops of focal liver lesions (FLLs) requires offline manual assessment by experienced radiologists, which is time-consuming and generates subjective results. Such assessment usually starts by manually identifying a reference frame, where FLL and healthy parenchyma are well-distinguished. This study proposes an automatic computational method to objectively identify the optimal reference frame for distinguishing and hence delineating an FLL, by statistically analyzing the temporal intensity variation across the spatially discretized ultrasonographic image. Level of confidence and clinical value of the proposed method were quantitatively evaluated on retrospective multi-institutional data (n = 64) and compared with expert interpretations. Results support the proposed method for facilitating easier, quicker and reproducible assessment of FLLs, further increasing the radiologists' confidence in diagnostic decisions. Finally, our method yields a useful training tool for radiologists, widening CEUS use in non-specialist centers, potentially leading to reduced turnaround times and lower patient anxiety and healthcare costs.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...