Related Experiment Video
Updated: Feb 26, 2026

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Intraoperative Ventilation of Morbidly Obese Patients Guided by Transpulmonary Pressure
Lars Eichler1, Katarzyna Truskowska2, A Dupree3
1Department of Anesthesiology and Critical Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20251, Hamburg, Germany. l.eichler@uke.de.
Background:
Bariatric surgery has proven a successful approach in the treatment of morbid obesity and its concomitant diseases such as diabetes mellitus and arterial hypertension. Aiming for optimal management of this challenging patient cohort, tailored concepts directly guided by individual patient physiology may outperform standardized care. Implying esophageal pressure measurement and electrical impedance tomography-increasingly applied monitoring approaches to individually adjust mechanical ventilation in challenging circumstances like acute respiratory distress syndrome (ARDS) and intraabdominal hypertension-we compared our institutions standard ventilator regimen with an individually adjusted positive end expiratory pressure (PEEP) level aiming for a positive transpulmonary pressure (P L) throughout the respiratory cycle.
Methods:
After obtaining written informed consent, 37 patients scheduled for elective bariatric surgery were studied during mechanical ventilation in reverse Trendelenburg position. Before and after installation of capnoperitoneum, PEEP levels were gradually raised from a standard value of 10 cm H2O until a P L of 0 +/- 1 cm H2O was reached. Changes in ventilation were monitored by electrical impedance tomography (EIT) and arterial blood gases (ABGs) were obtained at the end of surgery and 5 and 60 min after extubation, respectively.
Results:
To achieve the goal of a transpulmonary pressure (P L) of 0 cm H2O at end expiration, PEEP levels of 16.7 cm H2O (95% KI 15.6-18.1) before and 23.8 cm H2O (95% KI 19.6-40.4) during capnoperitoneum were necessary. EIT measurements confirmed an optimal PEEP level between 10 and 15 cm H2O before and 20 and 25 cm H2O during capnoperitoneum, respectively. Intra- and postoperative oxygenation did not change significantly.
Conclusion:
Patients during laparoscopic bariatric surgery require high levels of PEEP to maintain a positive transpulmonary pressure throughout the respiratory cycle. EIT monitoring allows for non-invasive monitoring of increasing PEEP demand during capnoperitoneum. Individually adjusted PEEP levels did not result in improved postoperative oxygenation.
More Related Videos
04:12Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...