Electrohydrodynamic instability of ion-concentration shock wave in electrophoresis

Rahul Gaur1, Supreet Singh Bahga1

  • 1Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India.

Physical Review. E
|July 16, 2017
PubMed

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
1.3K
Electrophoresis: Overview01:20

Electrophoresis: Overview

Electrophoresis is a powerful analytical separation technique that relies on the differential migration of charged species when subjected to an electric field. The core strength of electrophoresis lies in its ability to separate high-molecular-weight species in complex mixtures. It has found widespread use in biochemistry, molecular biology, and analytical chemistry, allowing the separation of compounds like amino acids, nucleotides, carbohydrates, and proteins with excellent resolution.
There...
4.4K
Shock Waves01:16

Shock Waves

While deriving the Doppler formula for the observed frequency of a sound wave, it is assumed that the speed of sound in the medium is greater than the source's speed through it. When this condition is breached, a shock wave occurs.
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
2.6K
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.5K
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
1.5K
Electrostatic Boundary Conditions in Dielectrics01:27

Electrostatic Boundary Conditions in Dielectrics

When an electric field passes from one homogeneous medium to another, crossing the boundary between the two mediums imparts a discontinuity in the electric field. This results in electrostatic boundary conditions that depend on the type of mediums the field propagates through.
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity....
2.0K