Related Experiment Video
Updated: Feb 26, 2026

Murine Model of Central Venous Stenosis using Aortocaval Fistula with an Outflow Stenosis
Published on: July 11, 2019
Optimal sizing of iliac vein stents
Seshadri Raju1, William J Buck1, William Crim1
1The RANE Center at St. Dominic's Memorial Hospital, Jackson, MS, USA.
Abstract:
Background Iliac vein stenting has emerged as a therapeutic option in chronic venous disease. The optimal stent size is unknown but should match normal caliber at a minimum. Methods Teleology: The iliac-femoral outflow caliber was measured by Duplex in healthy volunteers to determine normal caliber. Patient IVUS data: The distribution curve of IVUS planimetry data in 345 chronic venous disease limbs was analyzed: values at the right tail end of the curve should approach normal values according to distribution theory. The optimal stent size was also projected using Poiseuille equation and Young's scaling rule. Results The optimal stent sizes in the common iliac, external iliac, and common femoral vein segments are: 16, 14, and 12 mm diameters, respectively. Conclusion Stent correction of iliac vein stenosis should aim to restore the lumen to the minimum recommended caliber during the initial procedure and later re-interventions.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care
Varicose Veins II: Diagnostic Studies and Interprofessional Care