Related Experiment Video
Updated: Feb 26, 2026

Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Patient-specific Finite Element Analysis of Fiber Post and Ferrule Design
Monise de Paula Rodrigues1, Priscilla Barbosa Ferreira Soares2, Andréa Dollores Correia Miranda Valdivia1
1Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Minas Gerais, Brazil.
Introduction:
A ferrule on anterior endodontic-treated teeth has been evaluated using clinical trials, in vitro tests, and finite element analysis (FEA). The patient-specific FEA with a nonuniform ferrule and nonlinear contact biting load associated with clinical validation can be used to predict failure.
Methods:
A patient was selected with both maxillary central incisors with different ferrule designs who received endodontic treatment and restoration using a fiber post, composite core, and computer aided design and computer aided manufacturing lithium disilicate ceramic crowns. Strain gauges were attached to the buccal surfaces of both teeth to record ceramic strain during bite force recording for FEA validation. Cone-beam computed tomographic imaging was performed, and the Digital Imaging and Communication in Medicine files were exported to Mimics, 3-Matic (Materialise, Leuven, Belgium) and Patran (MSC Software, Santa Ana, CA) software to create a patient-specific FEA model. Bite load was applied using contact load applied by antagonist teeth (155 N). Mechanical properties were obtained from the literature. Modified von Mises equivalent stress was used for stress evaluation.
Results:
Stresses on the dentin and fiber post on the left incisor, which had a nonuniform ferrule, were higher compared with the right incisor. The strain values recorded for the right central incisor (strain gauge =79.9 ± 3.8 μS and FEA = 69.5 μS) and the left central incisor (strain gauge = 83.5 ± 5.3 μS and FEA = 73.9 μS) validate the FEA analysis.
Conclusions:
FEA was validated with in vivo strain values measured at the buccal crown surfaces, supporting that the stress levels were realistic for investigation of the clinical performance of fiber posts. Maintaining a uniform ferrule was more favorable than a localized higher ferrule.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
09:54Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
Related Concept Videos
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Design of Prismatic Beams for Bending
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Stress Concentrations in Circular Shafts
Design of Transmission Shafts - Stress Analysis