Related Experiment Video
Updated: Feb 26, 2026

Real-time Iontophoresis with Tetramethylammonium to Quantify Volume Fraction and Tortuosity of Brain Extracellular Space
Published on: July 24, 2017
Determination of iodide and total iodine in estuarine waters by cathodic stripping voltammetry using a vibrating
Estrella Espada-Bellido1, Zhaoshun Bi1, Pascal Salaün1
1Department of Earth and Ocean Sciences, University of Liverpool, Brownlow Street, Liverpool L69 3GP, UK.
Abstract:
Iodide in natural waters is an important nutrient to aquatic organisms and its determination is of relevance to marine aquaculture. For this reason it is of interest to have a simple analytical method for determination of iodide in water samples. Iodide in seawater can be determined electrochemically by cathodic stripping voltammetry (CSV) with a mercury drop electrode which has environmental drawbacks. In an attempt to minimise the use of mercury in voltammetry, a vibrating silver amalgam microwire electrode is used here for the determination by CSV of iodide speciation in natural waters including seawater. Microwire electrodes were made from silver wires (diameter: 12.5µm) and electrochemically coated with mercury. The electrode surface was stable for extended periods of analyses (at least one week) and was then replaced. The optimised conditions include a pH 8, a frequency of 500Hz and a deposition time of 60s, among others. The microwire was reactivated between scans using a conditioning potential at -3 V for 1s. The detection limit for iodide in seawater was found to be 0.7nM I- at a deposition time of 60s. The response increased linearly with the concentration of iodide in seawater up to 100nM I-. The method was successfully applied to various samples from the estuary of the river Mersey (Liverpool Bay). An existing procedure for iodine speciation was modified to enable determination of iodate and total iodine as well as iodide in estuarine waters.
More Related Videos
09:36In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Redox Titration: Iodimetry and Iodometry
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitation Titration Curve: Analysis
Electrodeposition
Electrodeposition can...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...