Yin-Shun Zhang1, Jian-Xiang Zhang1, Qing-Guo Yang1
1Department of Orthopaedics, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Background Context:
Surgical treatment for unstable atlas fractures has evolved in recent decades from C1-C2 or C0-C2 fusion to motion-preservation techniques of open reduction and internal fixation (ORIF). However, regardless of a transoral or a posterior approach, the reduction is still not satisfactory.
Purpose:
The article describes and evaluates a new technique for treating unstable atlas fractures by using a monoaxial screw-rod system.
Study Design:
This is a retrospective study.
Patient Sample:
The sample includes adult patients with unstable C1 fractures treated with a posterior monoaxial screw-rod system.
Outcome Measures:
The outcome measures included a visual analog pain scale, radiographic reduction (lateral mass displacement [LMD]), maintenance of reduction, C1-C2 instability (anterior atlantodens interval), and complications.
Materials And Methods:
From August 2013 to May 2016, nine consecutive patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with posterior ORIF by using a monoaxial screw-rod system. The medical records and the preoperative and postoperative radiographs were reviewed. Preoperative and postoperative computed tomography scans were used to specify the fracture types and to assess the reduction.
Results:
All nine patients with a mean age of 50.3 years successfully underwent surgery with this technique, and a follow-up of 17.4±9.3 months was performed. Transverse atlantal ligament (TAL) injury was found in eight of the nine patients: one of type I and seven of type II. The preoperative LMD averaged 7.0±2.2 mm and was restored completely after surgery; all the fractures achieved bony healing without loss of reduction or implant failure. None of the patients had complications of neurologic deficit, vertebral artery injury, or wound infection associated with the surgical procedure. Two patients complained of greater occipital nerve neuralgia after the operation, which gradually disappeared in 1 month. All patients had a well-preserved range of motion of the upper cervical spine at the final follow-up.
Conclusions:
Posterior osteosynthesis with a monoaxial screw-rod system is capable of an almost anatomical reduction for the unstable atlas fractures. The TAL incompetence may not be a contraindication to ORIF for C1 fractures, but the long-term effect of C1-C2 instability remains to be further investigated.