Background:
Contrast-enhanced CT is necessary before donor nephrectomy and is usually combined with a Tc-99m-mercapto-acetyltriglycine (MAG3) scan to check split renal function (SRF). However, all transplant programs do not use MAG3 because of its high cost and exposure to radiation. We examined whether CT volumetry of the kidney can be a new tool for evaluating SRF.
Methods:
Sixty-three patients underwent live donor nephrectomy. Patients without a 1.0 mm slice CT or follow-up for <12 months were excluded leaving 34 patients' data being analyzed. SRF was measured by MAG3. Split renal volume (SRV) was calculated automatically using volume analyzer software. The correlation between SRF and SRV was examined. The association between the donor's postoperative estimated glomerular filtration rate (eGFR) and predicted eGFR calculated by MAG3 or CT volumetry was analyzed at 1, 3, and 12 months post nephrectomy.
Results:
Strong correlations were observed preoperatively in a Bland-Altman plot between SRF measured by MAG3 and either CT cortex or parenchymal volumetry. In addition, eGFR after donation correlated with SRF measured by MAG3 or CT volumetry. The correlation coefficients (R) for eGFR Mag3 split were 0.755, 0.615, and 0.763 at 1, 3 and 12 months, respectively. The corresponding R values for cortex volume split were 0.679, 0.638, and 0.747. Those for parenchymal volume split were 0.806, 0.592, and 0.764.
Conclusion:
Measuring kidney by CT volumetry is a cost-effective alternative to MAG3 for evaluating SRF and predicting postoperative donor renal function. Both cortex and parenchymal volumetry were similarly effective.
Related Concept Videos
Kidney Transplant II: Surgical Procedure
Kidney Transplant I: Introduction
Imaging Studies III: Computed Tomography
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...