Related Experiment Video
Updated: Feb 26, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Novel radiation dose reduction fluoroscopic technology facilitates chronic total occlusion percutaneous coronary
Stephen Balter1, Matthew Brinkman, Sanjog Kalra
1Herbert and Sandi Feinberg Interventional Cardiology and Heart Valve Center at Columbia University Medical Center/New York-Presbyterian Hospital, New York, NY, USA.
Aims:
Radiation exposure and prolonged procedure time continue to limit the complexity of CTO-PCI procedures attempted. This study aimed to assess the impact of radiation dose-limiting equipment on radiation dosage and fluoroscopic time in chronic total occlusion (CTO) percutaneous coronary interventions (PCI).
Methods And Results:
Retrospective clinical and dosimetric data from diagnostic catheterisations (DXC) and CTO-PCI procedures performed on one of three variants of interventional fluoroscopic equipment were collected. Fluoroscopic time, air kerma, kerma area product and contrast utilisation were stratified by procedure type and compared among equipment types. To standardise comparisons among equipment configurations, an efficiency index (EI) was calculated. In total, 2,947 DXC and 276 CTO-PCI procedures were studied. For DXC, radiation dose (AK) decreased by 45% (despite modest increases in fluoroscopic time [FT]) between the reference (REF) and moderately dose-optimised (ECO) machines. A further 20% decrease in AK was observed on the highly dose-optimised machine (CLA). For CTO-PCI, AK declined by almost half (48%), despite a 76% increase in FT and higher procedural success rates (69.8% versus 83.0%) between REF and CLA. • Conclusions: Novel dose-optimised fluoroscopic equipment allows longer FT with a decrease in radiation dose to both patient and operator. This should allow operators to undertake increasingly longer and more complex procedures and reduce operators' lifetime irradiation.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Coronary Artery Disease V: Interprofessional Care
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Coronary Artery Disease IV: Preventive Measures
Cardiac Catheterization IV: Nursing Management