Variable-Volume Kinetic Model to Estimate Absolute Blood Volume in Patients on Dialysis Using Dialysate Dilution
Abstract:
Long- and short-term adverse outcomes in hemodialysis (HD) have been associated with intradialytic hypotension, a common HD complication and significant cause of morbidity. It has been suggested that knowledge of absolute blood volume (ABV) could be used to significantly improve treatment outcomes. Different dilution-based protocols have been proposed for estimating ABV, all relying on the classic mono-exponential back-extrapolation algorithm (BEXP). In this paper, we introduce a dialysate dilution protocol and an estimation algorithm based on a variable-volume, two-compartment, intravascular blood water content kinetic model (VVKM). We compare ABV estimates derived using the two algorithms in a dialysate dilution study including three arterio-venous (AV) and three central-venous (CV) access patients, and multiple bolus injection tests (3-5) within each of several (2-6) HD treatments. The distribution of differences between ABV estimated from the two methods showed negligible systematic difference between the mean values of ABVs estimated from the BEXP and VVKM algorithms, however, the VVKM estimates were 53% and 42% more precise for the CV and AV patients, respectively. Good agreement was observed between measured and VVKM-estimated blood water concentration with the root-mean-square error (RMSE) less than 0.02 kg/kg (2%) and 0.03 kg/kg (3%) for AV and CV patients, respectively. The dilution protocol and the new VVKM-based estimation algorithm offer a noninvasive, inexpensive, safe, and practical approach for ABV estimation in routine HD settings.
More Related Videos
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
Related Concept Videos
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Estimation of k and VD of Aminoglycosides