Body composition measurement using computed tomography: Does the phase of the scan matter?
Katie E Rollins1, Hannah Javanmard-Emamghissi1, Amir Awwad2
1Gastrointestinal Surgery, Nottingham Digestive Diseases Centre, National Institute for Health Research Biomedical Research Centre, Nottingham University Hospitals and University of Nottingham, Queen's Medical Centre, Nottingham, UK.
Computed tomography (CT) scan phase impacts body composition analysis. Contrast-enhanced CT scans may underestimate fat mass, but skeletal muscle index remains consistent, regardless of intravenous contrast presence.
Area of Science:
- Radiology
- Medical Imaging
- Body Composition Analysis
Background:
- Accurate body composition analysis using computed tomography (CT) is crucial for clinical assessments.
- The influence of intravenous contrast agents on CT-based body composition measurements is not fully understood.
- Standardization of CT imaging protocols is essential for reliable and reproducible body composition data.
Purpose of the Study:
- To investigate the methodological impact of intravenous contrast on body composition variables derived from CT imaging.
- To compare body composition metrics obtained from noncontrast, arterial, and portovenous phase CT scans.
- To assess the effect of scan phase on skeletal muscle index (SMI), fat mass (FM), and fat-free mass (FFM).
Main Methods:
- Analysis of triphasic abdominal CT scans (noncontrast, arterial, portovenous) from 111 patients.
- Utilized SliceOmatic software for quantitative analysis at the L3 vertebral level.
- Measured skeletal muscle index (SMI), fat mass (FM), fat-free mass (FFM), and skeletal muscle Hounsfield units (SMHU).
Main Results:
- Mean skeletal muscle Hounsfield units (SMHU) varied significantly across scan phases, increasing with contrast.
- Fat mass (FM) was significantly lower in arterial and portovenous phases compared to noncontrast scans.
- Fat-free mass (FFM) and skeletal muscle index (SMI) showed no significant differences between scan phases.
Conclusions:
- Standardization of CT scan phase is recommended for defining and analyzing myosteatosis.
- While contrast affects FM and SMHU, its impact on FFM and SMI appears minimal.
- Further research is needed to determine the clinical significance of these phase-dependent differences in outcome prediction.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT