Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Solid sampling ETV-ICPOES coupled to a nebulization/pre-evaporation system for direct elemental analysis of glutinous
Nausheen Sadiq1, Lily Huang1, Farhad Kaveh2
1Department of Chemistry, Queen's University, 90 Bader Lane, Kingston, Ontario K7L 3N6, Canada.
Abstract:
Because glutinous rice flour is consumed by millions of individuals around the world, its analysis is essential to ensure its safety. Solid sampling electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICPOES) allows for a quick analysis, precluding the need for time-consuming acid digestion that may also lead to analyte loss or contamination. However, the amount of sample that can be introduced without extinguishing the plasma is limited to about 4mg. The increase in plasma robustness resulting from the concurrent introduction of pre-evaporated water aerosol allows the introduction of 8mg of solid sample without extinguishing the plasma. This modified set-up was compared to conventional ETV for the determination of several elements in three different brands of glutinous rice flour. Not only are detection limits improved, but dried aqueous standard solutions can be used for external calibration, thereby significantly increasing the applicability of solid sampling ETV-ICPOES.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
09:46Reducing Willow Wood Fuel Emission by Low Temperature Microwave Assisted Hydrothermal Carbonization
Published on: May 19, 2019
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...