Related Experiment Video
Updated: Feb 25, 2026

Dynamic Digital Biomarkers of Motor and Cognitive Function in Parkinson's Disease
Published on: July 24, 2019
Patients with Parkinson disease present high ambulatory blood pressure variability
Hélcio Kanegusuku1, Carla Silva-Batista1, Tiago Peçanha1
1School of Physical Education and Sport, University of Sao Paulo, Sao Paulo, Brazil.
Abstract:
Patients with Parkinson disease (PD) present blunted nocturnal blood pressure fall and similar ambulatory blood pressure variability (ABPV) measured by standard deviation (SD) and coefficient of variation (CV) compared with healthy subjects. However, these classical indices of ABPV have limited validity in individuals with circadian blood pressure alterations. New indices, such as the average of daytime and night-time standard deviation weighted by the duration of the daytime and night-time intervals (SDdn ) and the average real variability (ARV), remove the influence of the daytime and the night-time periods on ABPV. This study assessed ABPV by SDdn and ARV in PD. Twenty-one patients with PD (11 men, 66 ± 2 years, stages 2-3 of modified Hoehn & Yahr) and 21 matched controls without Parkinson disease (9 men, 64 ± 1 years old) underwent blood pressure monitoring for 24 h. ABPV was analysed by 24 h, daytime and night-time SD and CV, and by the SDdn and ARV. Systolic/diastolic 24-h and night-time SD and CV were similar between the patients with PD and the controls. The patients with PD presented higher daytime systolic/diastolic CV and SD than the controls (10·4 ± 0·9/12·3 ± 0·8 versus 7·0 ± 0·3/9·9 ± 0·5%, P<0·05; 12·6 ± 1·0/9·1 ± 0·5 versus 8·6 ± 0·4/7·5 ± 0·3 mmHg, P<0·05, respectively) as well as higher systolic/diastolic SDdn (10·9 ± 0·8/8·2 ± 0·5 versus 8·2 ± 0·3/7·1 ± 0·2 mmHg, P<0·05, respectively) and ARV (8·8 ± 0·6/6·9 ± 0·3 versus 7·2 ± 0·2/6·0 ± 0·2 mmHg, P<0·05, respectively). In conclusion, patients with PD have higher ABPV than control subjects as assessed by SDd , CVd , SDdn and AVR.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

