Related Experiment Video
Updated: Jul 26, 2026

Measuring Plant Cell Wall Extension (Creep) Induced by Acidic pH and by Alpha-Expansin
Published on: March 11, 2009
A Procedure to Measure the in-Situ Hygrothermal Behavior of Earth Walls
Pierre-Antoine Chabriac1,2, Antonin Fabbri3, Jean-Claude Morel4
1Agence de l'Environnement et de Maitrise de l'Energie, 20 avenue du Grésillé, BP 90406, 49004 Angers Cedex 01, France. pierre-antoine.chabriac@entpe.fr.
Abstract:
Rammed earth is a sustainable material with low embodied energy. However, its development as a building material requires a better evaluation of its moisture-thermal buffering abilities and its mechanical behavior. Both of these properties are known to strongly depend on the amount of water contained in wall pores and its evolution. Thus the aim of this paper is to present a procedure to measure this key parameter in rammed earth or cob walls by using two types of probes operating on the Time Domain Reflectometry (TDR) principle. A calibration procedure for the probes requiring solely four parameters is described. This calibration procedure is then used to monitor the hygrothermal behavior of a rammed earth wall (1.5 m × 1 m × 0.5 m), instrumented by six probes during its manufacture, and submitted to insulated, natural convection and forced convection conditions. These measurements underline the robustness of the calibration procedure over a large range of water content, even if the wall is submitted to quite important temperature variations. They also emphasize the importance of gravity on water content heterogeneity when the saturation is high, as well as the role of liquid-to-vapor phase change on the thermal behavior.
More Related Videos
08:25Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
09:39Production and Testing of Moisture Behavior and Thermal Properties of Rapeseed Straw and Ganoderma resinaceum Mycelium Bio-Composites
Published on: September 5, 2025
Related Concept Videos
Masonry Cavity Walls
Maintaining a clean cavity during construction is...
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Expansion and Contraction in Masonry Walls
To...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units and sand dry and...
Measurement of Air Content in Concrete
The pressure method,...