Related Experiment Video
Updated: Feb 24, 2026

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Improved success rates using videolaryngoscopy in unexperienced users: a randomized crossover study in airway
Hendrik Eismann1, Lion Sieg1, Nicola Etti1
1Department of Anaesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Background:
Videolaryngoscopy has been proven to be a safe procedure managing difficult airways in the hands of airway specialists. Information about the success rates in unexperienced users of videolaryngoscopy compared to conventional laryngoscopy is sparse. Therefore, we aimed to evaluate if there might be more success in securing an airway if the unexperienced provider is using a videolaryngoscope in simulated airways in a randomized manikin study. Differences between commonly used videolaryngoscopes were elucidated.
Methods:
A standardized hands-on workshop prior to the study was performed. For direct laryngoscopy (DL) we used a Macintosh laryngoscope, whereas for videolaryngoscopy (VL) we used the cMac, the dBlade, and a King Vision videolaryngoscope. Endotracheal intubations in three simulated normal and difficult airways were performed. Main outcome parameters were time to view and time to intubation. Cormack and Lehane (C + L) classification and the percentage of glottic opening (POGO) score were evaluated. After every intubation, the participants were asked to review the airway and the device used.
Results:
22 participants (14.8 ± 4.0 intubations per year, mostly trauma surgeons) with limited experience in videolaryngoscopy (mean total number of videolaryngoscopy .4 ± .2) were enrolled. We found improved C + L grades with VL in contrast to DL. We saw similar data with respect to the POGO score, where the participants achieved better visibility of the glottis with VL. The hyperangulated blade geometries of videolaryngoscopes provided a better visibility in difficult airways than the standard geometry of the Macintosh-type blade. The subjective performance of the VL devices was better in more difficult airway scenarios.
Conclusions:
After a short introduction and hands-on training, a videolaryngoscope seems to be safe and usable by unexperienced providers. We assume a standard geometry laryngoscope is optimal for a patient with normal anatomy, whereas VL device with a hyperangulated blade is ideal for difficult airway situations with limited mouth opening or restricted neck movement.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....