Related Experiment Video
Updated: Feb 24, 2026

Nonradioactive Assay to Measure Polynucleotide Phosphorylation of Small Nucleotide Substrates
Published on: May 8, 2020
Microchip electrophoresis utilizing an in situ photopolymerized Phos-tag binding polyacrylamide gel for specific
Sachio Yamamoto1, Miyuki Himeno, Masaya Kobayashi
1Faculty of Pharmacy, Kindai University, 3-4-1 Kowakae, Higashi-osaka, Osaka, Japan. yamamoto@phar.kindai.ac.jp.
Abstract:
A method was developed for the specific entrapment and separation of phosphorylated compounds using a Phos-tag polyacrylamide gel fabricated at the channel crossing point of a microfluidic electrophoresis chip. The channel intersection of the poly(methyl methacrylate)-made microchip was filled with a solution comprising acrylamide, N,N-methylene-bis-acrylamide, Phos-tag acrylamide, and 2,2'-azobis[2-methyl-N-(2-hydroxyethyl)propionamide], which functioned as a photocatalytic initiator. In situ polymerization at the channel crossing point was performed by irradiation with a UV LED laser beam. The fabricated Phos-tag gel (100 × 100 × 30 μm) contains ca. 20 fmol of the Phos-tag group and therefore could entrap phosphorylated compounds at the femtomolar level. The electrophoretically trapped phosphorylated compounds were released from the gel by switching the voltage to deliver high concentrations of phosphate and EDTA in a background electrolyte. The broad sample band eluted from the gel was effectively reconcentrated at the boundary of a pH junction generated by sodium ions delivered from the outlet reservoir. The reconcentrated sample components were then separated and fluorometrically detected at the end of the separation channel. Under the optimized conditions, the phosphorylated compounds were concentrated by a factor of 100-fold, and the peak resolution was comparable to that obtained by pinched injection. This method was successfully utilized to preconcentrate and analyze phosphorylated peptides in a complex peptide mixture.
More Related Videos
11:35Screening for Functional Non-coding Genetic Variants Using Electrophoretic Mobility Shift Assay EMSA and DNA-affinity Precipitation Assay DAPA
Published on: August 21, 2016
08:55Rab10 Phosphorylation Detection by LRRK2 Activity Using SDS-PAGE with a Phosphate-binding Tag
Published on: December 14, 2017
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation