The physiological strain incurred during electrical utilities work over consecutive work shifts in hot environments:
Robert D Meade1, Andrew W D'Souza1, Lovely Krishen2
1a Human and Environmental Physiology Research Unit, School of Human Kinetics , University of Ottawa , Ottawa , ON , Canada.
Purpose:
In this article, we evaluated physiological strain in electrical utilities workers during consecutive work shifts in hot outdoor conditions.
Methods:
Four highly experienced electrical utilities workers were monitored during regularly scheduled work performed in hot conditions (∼34°C) on two consecutive days. Worker hydration (urine specific gravity) was assessed prior to and following work. The level of physical exertion was determined by video analysis. Body core temperature (Tcore) and heart rate (HR; presented as a percentage of maximum, %HRmax) were monitored continuously. Responses were reported for each worker individually and as a group mean ± standard deviation.
Results:
According to current guidelines, all workers were dehydrated prior to work on both days (urine specific gravity: day 1, 1.025 ± 0.005; day 2, 1.029 ± 0.004) and remained dehydrated following work (urine specific gravity: day 1, 1.027 ± 0.015; day 2, 1.032 ± 0.004) except for one worker on day 1 (urine specific gravity of 1.005). On day 1, the proportion of the work shift spent at rest (as defined by the American Conference for Governmental and Industrial Hygienists, ACGIH) was 51 ± 15% (range: 30-64%). Time spent resting increased in all workers on the second day reaching 66 ± 5% (range: 60-71%) of the work shift. Work shift average Tcore was 37.6 ± 0.1°C (range: 37.5-37.7°C) and 37.7 ± 0.2°C (range: 37.5-37.9°C) on days 1 and 2, respectively. Peak Tcore surpassed the ACGIH recommended threshold limit of 38.0°C for work in the heat in three workers on day 1 (38.1 ± 0.2°C, range: 37.8-38.2°C) while all workers exceeded this threshold on day 2 (38.4 ± 0.2°C, range: 38.2-38.7°C). By contrast, work shift average (day 1, 67 ± 7%HRmax, range: 59-74%HRmax; day 2, 65 ± 4%HRmax, range: 60-70%HRmax) and peak (day 1, 90 ± 6%HRmax, range: 83-98%HRmax; day 2, 87 ± 10%HRmax, range: 73-97%HRmax) HR were similar between days.
Conclusion:
This case report demonstrates elevations in thermal strain over consecutive work shifts despite decreases in work effort in electrical utilities workers during regular work in the heat.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Related Concept Videos
Responses to Heat and Cold Stress
Factors Affecting Body Temperature
Factors may include:
Thermal Stress
Thermal Strain
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes