Related Experiment Video
Updated: Feb 24, 2026

Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Determining the Probability of Achieving a Successful Quantitative Analysis for Gas Chromatography-Mass Spectrometry
David K Pinkerton1, Brooke C Reaser1, Kelsey L Berrier1
1Department of Chemistry, University of Washington , Box 351700, Seattle, Washington 98195, United States.
Abstract:
A new approach is presented to determine the probability of achieving a successful quantitative analysis for gas chromatography coupled with mass spectrometry (GC-MS). The proposed theory is based upon a probabilistic description of peak overlap in GC-MS separations to determine the probability of obtaining a successful quantitative analysis, which has its lower limit of chromatographic resolution Rs at some minimum chemometric resolution, Rs*; that is to say, successful quantitative analysis can be achieved when Rs ≥ Rs*. The value of Rs* must be experimentally determined and is dependent on the chemometric method to be applied. The approach presented makes use of the assumption that analyte peaks are independent and randomly distributed across the separation space or are at least locally random, namely, that each analyte represents an independent Bernoulli random variable, which is then used to predict the binomial probability of successful quantitative analysis. The theoretical framework is based on the chromatographic-saturation factor and chemometric-enhanced peak capacity. For a given separation, the probability of quantitative success can be improved via two pathways, a chromatographic-efficiency pathway that reduces the saturation of the sample and a chemometric pathway that reduces Rs* and improves the chemometric-enhanced peak capacity. This theory is demonstrated through a simulation-based study to approximate the resolution limit, Rs*, of multivariate curve resolution-alternating least-squares (MCR-ALS). For this study, Rs* was determined to be ∼0.3, and depending on the analytical expectations for the quantitative bias and the obtained mass-spectral match value, a lower value of Rs* ∼ 0.2 may be achievable.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...