Related Experiment Video
Updated: Sep 28, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Tile-Based Pairwise Analysis of GC × GC-TOFMS Data to Facilitate Analyte Discovery and Mass Spectrum Purification
Caitlin N Cain1, Timothy J Trinklein1, Grant S Ochoa1
1Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195-1700, United States.
Abstract:
A new tile-based pairwise analysis workflow, termed 1v1 analysis, is presented to discover and identify analytes that differentiate two chromatograms collected using comprehensive two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC-TOFMS). Tile-based 1v1 analysis easily discovered all 18 non-native analytes spiked in diesel fuel within the top 30 hits, outperforming standard pairwise chromatographic analyses. However, eight spiked analytes could not be identified with multivariate curve resolution-alternating least-squares (MCR-ALS) nor parallel factor analysis (PARAFAC) due to background contamination. Analyte identification was achieved with class comparison enabled-mass spectrum purification (CCE-MSP), which obtains a pure analyte spectrum by normalizing the spectra to an interferent mass channel (m/z) identified from 1v1 analysis and subtracting the two spectra. This report also details the development of CCE-MSP assisted MCR-ALS, which removes the identified interferent m/z from the data prior to decomposition. In total, 17 out of 18 spiked analytes had a match value (MV) > 800 with both versions of CCE-MSP. For example, MCR-ALS and PARAFAC were unable to decompose the pure spectrum of methyl decanoate (MVs < 200) due to its low 2D chromatographic resolution (∼0.34) and high interferent-to-analyte signal ratio (∼30:1). By leveraging information gained from 1v1 analysis, CCE-MSP and CCE-MSP assisted MCR-ALS obtained a pure spectrum with an average MV of 908 and 964, respectively. Furthermore, tile-based 1v1 analysis was applied to track moisture damage in cacao beans, where 86 analytes with at least a 2-fold concentration change were discovered between the unmolded and molded samples. This 1v1 analysis workflow is beneficial for studies where multiple replicates are either unavailable or undesirable to save analysis time.
More Related Videos
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
12:11Capture Compound Mass Spectrometry - A Powerful Tool to Identify Novel c-di-GMP Effector Proteins
Published on: March 29, 2015
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Mass Spectrometry: Overview