Related Experiment Video
Updated: Feb 24, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Characterization of a stepwise approach in cavotricuspid isthmus ablation for typical atrial flutter: A randomized
José Manuel Rubín1, David Calvo1, Diego Pérez1
1Cardiology Department, Hospital Universitario Central de Asturias, Oviedo, Spain.
Introduction:
Our aim was to characterize a stepwise approach in cavotricuspid isthmus ablation for typical atrial flutter in a prospective, noncrossover randomized study.
Methods:
One hundred and fifty patients referred for cavotricuspid isthmus (CTI)-dependent atrial flutter ablation were randomized to undergo an ablation with an 8-mm-tip catheter (group 1), a 3.5-mm open irrigation-tip catheter (group 2), and a 3.5-mm open irrigation porous-tip catheter (group 3). A stepwise approach was performed, changing the ablation site from medial to septal aspects of the CTI, in case it was not effective without crossover between catheters.
Results:
CTI block was achieved in all the patients using only one catheter. There was a 68% efficacy in group 1, 40% in group 2, and 28% in group 3 to achieve CTI block within 10 minutes (P = 0.001) and 96%, 70%, and 70% in groups 1, 2, and 3, respectively, within 20 minutes (P = 0.002) of radiofrequency ablation. The 8-mm catheter was also faster in fluoroscopy time and CTI block time. There were no differences in efficiency in the both irrigated catheters. There were no significant differences in complications among three catheters.
Conclusions:
With this stepwise approach, it is possible to achieve CTI block in all cases, using a single catheter without crossover, with good times of procedure and with a low complication rate. The 8-mm solid catheter is faster than the other irrigated-tip catheters. The 3.5-mm open irrigation porous-tip catheter is as effective and safe as the conventional irrigated-tip catheter.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management