Related Experiment Video
Updated: Feb 23, 2026

Intramucosal Inoculation of Squamous Cell Carcinoma Cells in Mice for Tumor Immune Profiling and Treatment Response Assessment
Published on: April 22, 2019
Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography After Concurrent Chemoradiotherapy in Locally
Tim Van den Wyngaert1, Nils Helsen1, Laurens Carp1
1Tim Van den Wyngaert, Nils Helsen, Laurens Carp, Carl G. Van Laer, Jan B. Vermorken, and Sigrid Stroobants, Antwerp University Hospital, Edegem; Tim Van den Wyngaert, Laurens Carp, and Sigrid Stroobants, University of Antwerp, Wilrijk; Michel J. Martens, Algemeen Ziekenhuis (AZ) Turnhout, Turnhout; Isabel Hutsebaut and Sabine A.E. Meersschout, AZ Sint-Jan, Brugge; Philip R. Debruyne, AZ Groeninge, Kortrijk; Annelies L.M. Maes, Jessa Ziekenhuis, Hasselt; Joost van Dinther, Sint-Augustinus Hospital; Olivier Lenssen and Danielle Van den Weyngaert, Ziekenhuis Netwerk Antwerpen Middelheim, Antwerp, Belgium; Sara Hakim, Otto S. Hoekstra, and Remco De Bree, Vrije Universiteit Medical Center, Amsterdam; Remco De Bree, University Medical Center Utrecht, Utrecht, the Netherlands; and Philip R. Debruyne, Anglia Ruskin University, Chelmsford, United Kingdom.
Abstract:
Purpose To assess the standardized implementation and reporting of surveillance [18F]fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) scan of the neck in locoregionally advanced head-and-neck squamous cell carcinoma (LAHNSCC) after concurrent chemoradiotherapy (CCRT). Patients and Methods We performed a prospective multicenter study of FDG-PET/CT scanning 12 weeks after CCRT in newly diagnosed patients with LAHNSCC (stage IVa/b) that used standardized reconstruction and Hopkins reporting criteria. The reference standard was histology or > 12 months of clinical follow-up. The primary outcome measure was the negative predictive value (NPV) of FDG-PET/CT scans and other supporting diagnostic test characteristics, including time dependency with increasing follow-up time. Results Of 152 patients, 125 had adequate primary tumor control after CCRT and entered follow-up (median, 20.4 months). Twenty-three (18.4%) had residual neck disease. Overall, NPV was 92.1% (95% CI, 86.9% to 95.3%; null hypothesis: NPV = 85%; P = .012) with sensitivity of 65.2% (95% CI, 44.9% to 81.2%), specificity of 91.2% (95% CI, 84.1% to 95.3%), positive predictive value of 62.5% (95% CI, 45.5% to 76.9%), and accuracy of 86.4% (95% CI, 79.3% to 91.3%). Sensitivity was time dependent and high for residual disease manifesting up to 9 months after imaging but lower (59.7%) for disease detected up to 12 months after imaging. Standardized reporting criteria reduced the number of equivocal reports (95% CI for the difference, 2.6% to 15.0%; P = .003). Test characteristics were not improved with the addition of lymph node CT morphology criteria. Conclusion FDG-PET/CT surveillance using Hopkins criteria 12 weeks after CCRT is reliable in LAHNSCC except for late manifesting residual disease, which may require an additional surveillance scan at 1 year after CCRT to be detected.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
06:11Therapy Testing in a Spheroid-based 3D Cell Culture Model for Head and Neck Squamous Cell Carcinoma
Published on: April 20, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...