Related Experiment Video
Updated: Feb 23, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Clinical analysis of the approximate, 3-dimensional, biological effective dose equation in multiphase treatment plans
Kevin I Kauweloa1, Alonso N Gutierrez1, Angelo M Bergamo1
1Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, TX; Cancer Therapy and Research Center, San Antonio, TX.
Abstract:
A multiphase, approximate biological effective dose (BEDA) equation was introduced because most treatment planning systems (TPS) are incapable of calculating the true BED (BEDT). This work investigates the accuracy and precision of the multiphase BEDA relative to the BEDT in clinical cases. Ten patients with head and neck cancer and 10 patients with prostate cancer were studied using their treatment plans from Pinnacle3 9.2 (Philips Medical, Fitchburg, WI). The organs at risk (OARs) that were studied are the normal brain, left and right optic nerves, optic chiasm, spinal cord, brainstem, bladder, and rectum. BEDA and BEDT distributions were calculated using MATLAB 2010b (MathWorks, Natick, MA) and analyzed on a voxel basis for percent error, percent error volume histograms (PEVHs), Pearson correlation coefficient, and Bland-Altman analysis. The maximum BED values that were calculated using the BEDA and BEDT methods were also analyzed. BEDA was found to always underestimate BEDT. The accuracy and precision of BEDA distributions varied between the organs: for optic chiasm and brainstem, 50% of the patients had an overall BEDA percent error of <1%; for left and right optic nerves, rectum, and bladder, 60% to 70% of the patients had an overall BEDA percent error of <1%; and for normal brain and spinal cord, 80% of the patients had an overall BEDA percent error of <1%. BEDA distributions had maximum errors ranging from 2% to 11%, with the 11% error occurring for bladder. BEDA produced much more accurate maximum BED values with adjacent organs such as normal brain, bladder, and rectum. This study has shown that BEDA can calculate BED distributions with acceptable accuracy under certain circumstances. However, its consistency and accuracy strongly depend on the dose distributions of the different treatment phases. One should be cautious when using BEDA.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Biological Effects of Radiation
Three-Compartment Open Model
Pharmacodynamic Models: Linear Concentration–Effect Model
Dosage Regimens: Partial Pharmacokinetic Parameters
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Dosage Regimen: Multiple Oral Dosage