Related Experiment Video
Updated: Feb 23, 2026

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
A method for assessment of the dynamic response of the arterial baroreflex
M T Lund1, M Salomonsson1, T E N Jonassen1
1Department of Biomedical Sciences, University of Copenhagen, Copenhagen N, Denmark.
Aim:
The baroreflex is a key mechanism in cardiovascular regulation, and alterations in baroreceptor function are seen in many diseases, including heart failure, obesity and hypertension. We propose a new method for analysing baroreceptor function from continuous blood pressure (BP) and heart rate (HR) in both health and disease.
Methods:
Forty-eight-hour data series of BP and HR were collected with telemetry. Sprague Dawley rats on standard chow (n = 11) served as controls, while rats on a high-fat, high-fructose (HFHC) diet (n = 6) constituted the obese-hypertensive model. A third group of rats underwent autonomic blockade (n = 6). An autoregressive-moving-average with exogenous inputs (ARMAX) model was applied to the data and compared with the α-coefficient.
Results:
Autonomic blockade caused a significant reduction in the strength of the baroreflex as estimated by ARMAX [ARMAX- baroreflex sensitivity (BRS)] -0.03 ± 0.01 vs. -0.19 ± 0.04 bpm heartbeat-1) . Both methods showed a ~50% reduction in BRS in the obese-hypertensive group compared with control (body weight 531 ± 27 vs. 458 ± 19 g, P < 0.05; mean arterial pressure 119 ± 3 vs. 102 ± 1 mmHg, P < 0.05; ARMAX-BRS -0.08 ± 0.01 vs. -0.15 ± 0.01 bpm heartbeat-1 , P < 0.05; α-coefficient BRS 0.51 ± 0.07 vs. 0.89 ± 0.07 ms mmHg-1 , P < 0.05). The ARMAX method additionally showed the open-loop gain of the baroreflex to be reduced by ~50% in the obese-hypertensive group (-2.3 ± 0.3 vs. -4.1 ± 0.3 bpm, P < 0.05), while the rate constant was similar between groups.
Conclusion:
The ARMAX model represents an efficient method for estimating several aspects of the baroreflex. The open-loop gain of the baroreflex was attenuated in obese-hypertensive rats compared with control, while the time response was similar. The algorithm can be applied to other species including humans.
More Related Videos
08:41Assessment of Vascular Tone Responsiveness using Isolated Mesenteric Arteries with a Focus on Modulation by Perivascular Adipose Tissues
Published on: June 3, 2019
10:28Evaluation of Vascular Control Mechanisms Utilizing Video Microscopy of Isolated Resistance Arteries of Rats
Published on: December 5, 2017
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Regulation of the Cardiovascular System
The regulation of the cardiovascular system involves the autonomic nervous system (ANS), baroreceptors, and chemoreceptors, ensuring that heart rate and blood pressure are appropriately modulated in response to varying physiological demands.
The ANS comprises two main divisions: the sympathetic and parasympathetic nervous systems. The sympathetic nervous system enhances...