Related Experiment Video
Updated: Feb 23, 2026

Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment
Published on: May 2, 2025
Water Issues Related to Transitioning from Conventional to Unconventional Oil Production in the Permian Basin
Bridget R Scanlon1, Robert C Reedy1, Frank Male1
1Bureau of Economic Geology, Jackson School of Geosciences, University of Texas at Austin , 10100 Burnet Road, Austin, Texas 78758, United States.
Abstract:
The Permian Basin is being transformed by the "shale revolution" from a major conventional play to the world's largest unconventional play, but water management is critical in this semiarid region. Here we explore evolving issues associated with produced water (PW) management and hydraulic fracturing water demands based on detailed well-by-well analyses. Our results show that although conventional wells produce ∼13 times more water than oil (PW to oil ratio, PWOR = 13), this produced water has been mostly injected back into pressure-depleted oil-producing reservoirs for enhanced oil recovery. Unconventional horizontal wells use large volumes of water for hydraulic fracturing that increased by a factor of ∼10-16 per well and ∼7-10 if normalized by lateral well length (2008-2015). Although unconventional wells have a much lower PWOR of 3 versus 13 from conventional wells, this PW cannot be reinjected into the shale reservoirs but is disposed into nonproducing geologic intervals that could result in overpressuring and induced seismicity. The potential for PW reuse from unconventional wells is high because PW volumes can support hydraulic fracturing water demand based on 2014 data. Reuse of PW with minimal treatment (clean brine) can partially mitigate PW injection concerns while reducing water demand for hydraulic fracturing.
More Related Videos
12:18Pore-scale Imaging and Characterization of Hydrocarbon Reservoir Rock Wettability at Subsurface Conditions Using X-ray Microtomography
Published on: October 21, 2018
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
Related Concept Videos
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Bioremediation
Gradually Varying Flow
Water and Mineral Acquisition
Peritoneal Dialysis I: Introduction and Procedure
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...