Related Experiment Video
Updated: Feb 23, 2026

Robotic-Guided Stereoelectroencephalography for Invasive Epilepsy Monitoring
Published on: June 13, 2025
Efficacy and safety in frameless robot-assisted stereo-electroencephalography (SEEG) for drug-resistant epilepsy
I Ollivier1, C Behr2, H Cebula1
1Service de neurochirurgie, hôpital de Hautepierre, CHRU de Strasbourg, 1, avenue Molière, 67200 Strasbourg, France.
Introduction:
Stereo-electroencephalography (SEEG) is an invasive procedure, used to identify the epileptogenic zone that can be surgically removed in order to treat drug-resistant epilepsy. Frameless robot-assisted positioning of depth electrodes permits a 3D approach with different obliquities and trajectories. The objective of the present study was to evaluate the morbidity and the accuracy related to this frameless procedure.
Patients And Methods:
Sixty-six patients were managed wherein 901 electrodes were implanted during a 6-year-period. All patients had a postoperative CT-scan that was fused with preoperative MRI planning. In order to assess the accuracy of the procedure, the Euclidian distance was calculated between the coordinates of the planned trajectory and the actual position of the electrode at the entry point and at the target point for 857 electrodes.
Results:
Among the 66 patients, one (1.5%) experienced a symptomatic brain haematoma and one (1.5%) a stroke-like migraine after radiation therapy (SMART) syndrome. There was no permanent morbidity or mortality. Compared to the classical SEEG approach, a higher rate of asymptomatic postoperative bleeding was found on the CT-scan in 8 patients (12.1%). Any infectious events were recorded. The median accuracy of frameless robotic SEEG procedure was equivalent to a 1.1mm error deviation (0.15-2.48) at the entry point and 2.09mm (1.06-3.72) at the target point respectively, with no differences for double obliquity trajectories.
Conclusion:
Frameless robot-assisted SEEG appears to be a safe procedure, providing sufficient accuracy in order to delineate the epileptogenic zone and represents a helpful tool in the pre-surgical management of refractory epilepsy.
More Related Videos
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
04:50Operative Technique and Nuances for the Stereoelectroencephalographic SEEG Methodology Utilizing a Robotic Stereotactic Guidance System
Published on: June 9, 2023
Related Concept Videos
Antiepileptic Drugs: Potassium Channel Activators
Ezogabine has gained approval as an adjunctive treatment...
Epilepsy and Seizures: Overview
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...