Design strategies for improved velocity-selective pulse sequences.
1Department of Veterans Affairs Medical Center, San Francisco, CA 94121, United States; Department of Pharmaceutical Chemistry, University of California, San Francisco, CA, United States.
Magnetic Resonance Imaging
|September 12, 2017
Summary
New magnetic resonance imaging (MRI) methods improve blood flow visualization without contrast agents. These enhanced sequences offer sharper transitions and better stability for accurate flow measurement.
Area of Science:
- Medical Imaging
- Biophysics
- Magnetic Resonance Imaging
Background:
- Contrast-agent-free MRI methods visualize blood flow using flow-encoding gradients.
- Existing methods have limitations including poor transition sharpness, long scan times, and susceptibility to magnetic field variations.
Purpose of the Study:
- To develop improved radiofrequency (RF) pulse sequences for blood flow MRI.
- Enhance immunity to radiofrequency inhomogeneity and resonance offsets.
- Minimize sequence length while maintaining flow sensitivity.
Main Methods:
- Design modifications for existing long RF pulse sequences.
- Utilized Bloch equations simulations to test sequence performance.
- Evaluated sequences in the presence of blood flow and magnetic field imperfections.
Main Results:
- Developed new sequences with improved immunity to RF inhomogeneity and resonance offsets.
- Achieved sharp transitions between stationary and flowing spins.
- Demonstrated sequences suitable for 3.0 Tesla MRI systems.
Conclusions:
- The proposed design methods enhance the performance of blood flow MRI sequences.
- These improvements allow for more accurate and robust blood flow quantification.
- The optimized sequences are practical for clinical application at 3.0T.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
1.9K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.9K
Special considerations while measuring pulse
991
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
991