Related Experiment Video
Updated: Jan 30, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Comparison of 3 Derivatization Methods for the Analysis of Amphetamine-Related Drugs in Oral Fluid by Gas
Khaled M Mohamed1, Abdulsallam Bakdash1
1The Department of Forensic Chemistry, The College of Forensic Sciences, Naif Arab University for Security Sciences, Riyadh, Saudi Arabia.
Abstract:
The heptafluorobutyric anhydride (HFBA), pentafluoropropionic anhydride (PFPA), and trifluoroacetic anhydride (TFAA) are compared as derivatizing reagents to use as the optimal method for the analysis of 10 amphetamines and cathinones in oral fluid. The target compounds were amphetamine (AMP), methamphetamine (MA), 4-methylamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), cathinone (CAT), methcathinone, mephedrone, and ephedrine. Amphetamine-D5, MA-D5, MDA-D5, MDMA-D5, and MDEA-D5 use as internal standards (IS). The analytes and IS were extracted from 0.5 mL of oral fluid by ethyl acetate in the presence of NaOH (0.1 N) as the base and then the dried extracts were derivatized with HFBA, PFPA, or TFAA at 70°C for 30 minutes. The limits of quantification based on signal-to-noise ratios ≥10 were ranged between 2.5 and 10 ng/mL. The calibration graphs were linear in the range of 5 or 10 to 1000 ng/mL for all analytes. Based on sensitivity, the PFPA is proved to be the best for derivatization of the target compounds prior to gas chromatography-mass spectrometry analysis.
More Related Videos
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II