Related Experiment Video
Updated: Feb 23, 2026

Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
Cold sensing in grapevine-Which signals are upstream of the microtubular "thermometer"
1Molecular Cell Biology, Botanical Institute, Karlsruhe Institute of Technology, Fritz-Haber-Weg 4, 76131, Karlsruhe, Germany.
Abstract:
Plants can acquire freezing tolerance in response to cold but non-freezing temperatures. To efficiently activate this cold acclimation, low temperature has to be sensed and processed swiftly, a process that is linked with a transient elimination of microtubules. Here, we address cold-induced microtubules elimination in a grapevine cell line stably expressing a green fluorescent protein fusion of Arabidopsis TuB6, which allows to follow their response in vivo and to quantify this response by quantitative image analysis. We use time-course studies with several specific pharmacological inhibitors and activators to dissect the signalling events acting upstream of microtubules elimination. We find that microtubules disappear within 30 min after the onset of cold stress. We provide evidence for roles of calcium influx, membrane rigidification, and activation of NAD(P)H oxidase as factors in signal susception and amplification. We further conclude that a G-protein in concert with a phospholipase D convey the signal towards microtubules, whereas calmodulin seems to be not involved. Moreover, activation of jasmonate pathway in response to cold is required for an efficient microtubule response. We summarize our findings in a working model on a complex signalling hub at the membrane-cytoskeleton interphase that assembles the susception, perception and early transduction of cold signals.
Related Concept Videos
Responses to Heat and Cold Stress
Thermosensation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Physical Methods for Controlling Microbial Growth: Temperature
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Regulation of Transpiration by Stomata

