Quantitative assessment of prevalence of pre-analytical variables and their effect on coagulation assay. Can
1Graded Specialist (Pathology), Military Hospital Bhopal, MP, India.
Background:
Very few Indian studies exist on evaluation of pre-analytical variables affecting "Prothrombin Time" the commonest coagulation assay performed. The study was performed in an Indian tertiary care setting with an aim to assess quantitatively the prevalence of pre-analytical variables and their effects on the results (patient safety), for Prothrombin time test. The study also evaluated their effects on the result and whether intervention, did correct the results.
Methods:
The firstly evaluated the prevalence for various pre-analytical variables detected in samples sent for Prothrombin Time testing. These samples with the detected variables wherever possible were tested and result noted. The samples from the same patients were repeated and retested ensuring that no pre-analytical variable is present. The results were again noted to check for difference the intervention produced.
Results:
The study evaluated 9989 samples received for PT/INR over a period of 18 months. The prevalence of different pre-analytical variables was found to be 862 (8.63%). The proportion of various pre-analytical variables detected were haemolysed samples 515 (5.16%), over filled vacutainers 62 (0.62%), under filled vacutainers 39 (0.39%), low values 205 (2.05%), clotted samples 11 (0.11%), wrong labeling 4 (0.04%), wrong vacutainer use 2 (0.02%), chylous samples 7 (0.07%) and samples with more than one variable 17 (0.17%). The comparison of percentage of samples showing errors were noted for the first variables since they could be tested with and without the variable in place. The reduction in error percentage was 91.5%, 69.2%, 81.5% and 95.4% post intervention for haemolysed, overfilled, under filled and samples collected with excess pressure at phlebotomy respectively.
Conclusion:
Correcting the variables did reduce the error percentage to a great extent in these four variables and hence the variables are found to affect "Prothrombin Time" testing and can hamper patient safety.
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Venous Thrombosis III: Interprofessional Care
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...