Related Experiment Video
Updated: Feb 22, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Rapid determination of 18 glucocorticoids in serum using reusable on-line SPE polymeric monolithic column coupled
Hui Li1, Lianfeng Ai2, Sufang Fan3
1The Liver Disease Diagnosis and Treatment Center of PLA, Bethune International Peace Hospital, Shijiazhuang, 050082, PR China; Hebei Food Inspection and Research Institute, Shijiazhuang, 050091,PR China.
Abstract:
A simple, rapid and sensitive method for the simultaneous determination of 18 glucocorticoids in serum was developed by coupling on-line solid-phase extraction (SPE) polymeric monolithic column to a liquid chromatography-quadrupole/orbitrap high-resolution mass spectrometer. A simple poly(ethylene glycol dimethacrylate) monolith column (10mm×2.1mm i.d.) was fabricated, and the morphology, surface area and extraction performance of the monolithic column were characterized. Serum samples were extracted by acetonitrile (ACN). Then, online SPE was achieved on the synthesized monolithic column using a 10mmol/L ammonium acetate solution as the loading solvent. After the transfer from the monolith into analytical column (Capcell Pak ADME column) using ACN, the adsorbed analytes were separated on the analytical column and detected with a high-resolution hybrid quadrupole/orbitrap mass spectrometer with full scan/ddMS2 scan mode Under optimized conditions, the method was linear with target linear correlation coefficient (R2) higher than 0.995. Detection limits were in range of 0.1-0.6ng/mL, and the quantification limits were 0.3-1.5ng/mL. The recovery was between 71.9% and 89.2% in three spike levels with precision (n=5) of 5.40-12.1%. The serum sample was directly analyzed after a simple extraction procedure, and the on-line SPE and determination were achieved within only 16min. The method was used to analyze the dynamic contents variation of cortisone and hydrocortisone in serum before and after the surgery.
More Related Videos
10:59Glycomics-Guided Glycoproteomics Facilitates Comprehensive Profiling of the Glycoproteome in Complex Tumor Microenvironments
Published on: February 7, 2025
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...