Related Experiment Video
Updated: Feb 22, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Skin Surface Temperatures Measured by Thermal Imaging Aid in the Diagnosis of Cellulitis
Lauren N Ko1, Adam B Raff2, Anna C Garza-Mayers1
1Department of Dermatology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Abstract:
Warmth is a characteristic but nondiagnostic feature of cellulitis. We assessed the diagnostic utility of skin surface temperature in differentiating cellulitis from pseudocellulitis. Adult patients presenting to the emergency department of a large urban hospital with presumed cellulitis were enrolled. Patients were randomized to dermatology consultation (n = 40) versus standard of care (n = 32). Thermal images of affected and unaffected skin were obtained for each patient. Analysis was performed on dermatology consultation patients to establish a predictive model for cellulitis, which was then validated in the other cohort. Of those evaluated by dermatology consultation, pseudocellulitis was diagnosed in 28%. Cellulitis patients had an average maximum affected skin temperature of 34.1°C, which was 3.7°C warmer than the corresponding unaffected area (95% confidence interval = 2.7-4.8°C, P < 0.00001). Pseudocellulitis patients had an average maximum affected temperature of 31.5°C, which was 0.2°C warmer than the corresponding unaffected area (95% confidence interval = -1.1 to 1.5°C, P = 0.44). Temperature differences between sites were greater in cellulitis patients than in pseudocellulitis patients (3.7 vs. 0.2°C, P = 0.002). A logistic regression model showed that a temperature difference of 0.47°C or greater conferred a 96.6% sensitivity, 45.5% specificity, 82.4% positive predictive value, and 83.3% negative predictive value for cellulitis diagnosis. When validated in the other cohort, this model gave the correct diagnosis for 100% of patients with cellulitis and 50% of those with pseudocellulitis. A difference threshold of 0.47°C or greater between affected and unaffected skin showed an 87.5% accuracy in cellulitis diagnosis.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...