Weaver's historic accessible collection of synthetic dyes: a cheminformatics analysis

Melaine A Kuenemann1, Malgorzata Szymczyk2, Yufei Chen2

  • 1Department of Chemistry , Bioinformatics Research Center , College of Sciences , North Carolina State University , Raleigh , NC 27695 , USA .

Chemical Science
|September 30, 2017
PubMed

Related Concept Videos

Karyotyping01:17

Karyotyping

Describing the number and physical features of chromosomes can reveal abnormalities that underlie genetic diseases. This description is facilitated by special staining techniques that produce a particular banding pattern on each chromosome. State-of-the-art techniques make this approach even more powerful, enabling the detection of individual genes that cause disease.A Simple Chromosome Staining Technique Provides Valuable Scientific InsightSome genetic diseases can be detected by looking at...
Aryldiazonium Salts to Azo Dyes: Diazo Coupling01:11

Aryldiazonium Salts to Azo Dyes: Diazo Coupling

The reaction of weakly electrophilic aryldiazonium (also called arenediazonium) salts with highly activated aromatic compounds leads to the formation of products with an —N=N— link, called an azo linkage. This reaction, presented in Figure 1, is known as diazo coupling and occurs without the loss of the nitrogen atoms of the aryldiazonium salt. Highly activated aromatic compounds such as phenols or arylamines favor the diazo coupling reaction. The coupling generally occurs at the para position.
UV–Vis Spectroscopy of Conjugated Systems01:32

UV–Vis Spectroscopy of Conjugated Systems

Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent of conjugation in the...
Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...