High-volume steroid isotopic standards developed as working standards for gas chromatography-combustion-isotope ratio
Herbert J Tobias1,2, J Thomas Brenna1,2,3
1Division of Nutritional Sciences, Cornell University, Ithaca, New York.
Abstract:
High-precision carbon isotope ratio analysis of urinary steroids by gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) is the official test to detect illicit doping of synthetic versions of endogenous steroids, such as testosterone. Our group created the first steroid isotopic standards (SIS) specifically for World Anti-Doping Agency (WADA) accredited laboratories. The standards contain mixtures of steroids as acetates or free steroids at ~400 μg each per ampoule and have been widely distributed to anti-doping laboratories to facilitate comparability of inter-laboratory results. Here we report on the creation and characterization of 3 new high-volume single component SIS suitable for use as working standards. They contain ~50 times more steroid mass per ampoule than previous SIS. The new SIS, coded CU/PCC 40-1, CU/PCC 41-1, & CU/PCC 42-1, contain ~20 mg of androsterone, androsterone-AC, and 5α-cholestane, with determined isotopic values of -27.09 ± 0.07 mUr, -32.82 ± 0.01 mUr, -25.03 ± 0.01 mUr, respectively. We used our previously developed protocol to calibrate the isotopically uniform steroids against the isotopic standard gases methane and ethane in NIST RM 8559 that are traceable to the international standard Vienna PeeDee Belemnite (VPDB). Two sets of data, acquired 7 months apart, of absolute δ13 CVPDB and ∆Δδ13 CVPDB values from 8 randomly selected ampoules of all 3 SIS indicate uniformity of steroid isotopic composition within measurement reproducibility, SD(δ13 C) < 0.2 mUr Our results show that protocols for SIS extend to creation of high volume working standards that can also be used as internal standards under appropriate GC conditions.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview