Related Experiment Video
Updated: Feb 22, 2026

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
Published on: May 1, 2020
Dynamic instrumented palpation - a new method for soft tissue quality assessment: application to prostate disease
Th Jimmy Yang1, Simon Phipps2, Steve Kw Leung2
11 Institute of Mechanical, Process and Energy Engineering, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, UK.
None:
The objective is to establish the feasibility of using dynamic instrumented palpation, a novel technique of low-frequency mechanical testing, applied here to diagnose soft tissue condition. The technique is applied, in vitro, to samples of excised prostate gland affected by benign prostate hyperplasia and/or prostate cancer. Particular attention is paid to the relationship between the histological structure of the tissue and the dynamic mechanical properties in an attempt to separate patient-specific aspects from histopathological condition (i.e. prostate cancer or benign prostate hyperplasia). The technique is of clinical interest because it is potentially deployable in vivo. Prostate samples were obtained from a total of 36 patients who had undergone transurethral resection of the prostate to relieve prostatic obstruction and 4 patients who had undergone radical cystoprostatectomy for bladder cancer. Specimens (chips) recovered from transurethral resection of the prostate were of nominal size 5 mm × 8 mm and thicknesses between 2 and 4 mm, whereas those from the cystoprostatectomy were in the form of transverse slices of thickness approximately 6 mm. Specimens were mechanically tested by a controlled strain cyclic compression technique, and the resulting dynamic mechanical properties expressed as the amplitude ratio and phase difference between the cyclic stress and cyclic strain. After mechanical testing, the percentage areas of glandular and smooth muscle were measured at each probe point. Good contrast between the dynamic modulus of chips from benign prostate hyperplasia and prostate cancer patients was demonstrated, and absolute values similar to those published by other authors are reported. For the slices, modulus values were considerably higher than for chips, and good in-patient mechanical contrast was revealed for predominantly nodular and predominantly stromal areas. Extending this classification between patients required pattern recognition techniques. Overall, the study has demonstrated that dynamic mechanical properties can potentially be used for diagnosis of prostate condition using in vivo measurements.
Related Concept Videos
Assessment of the Abdomen III: Palpation
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...
Data Collection III
The principles to begin the physical assessment include conducting a comprehensive or problem-related history in a quiet, well-lit room, emphasizing privacy and comfort for the...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...