Related Experiment Video
Updated: May 31, 2025

A Novel Approach to Monitoring Graft Neovascularization in the Human Gingiva
Published on: January 12, 2019
Global observational survey verifying surgeon utilization of the Validated Intraoperative Bleeding (VIBe) scale for
Pierre R Tibi1, Abe DeAnda2, Steve Kw Leung3
1Department of Cardiothoracic and Vascular Services, Yavapai Regional Medical Center, Prescott, AZ, USA.
Introduction:
Based on US-FDA guidelines to create tools for development and evaluation of medical devices in non-clinical and clinical studies, the Validated Intraoperative Bleeding (VIBe) Scale was developed. The current investigation expands upon the earlier validation study with multi-specialty surgeons to further corroborate these findings and establish feasibility to implement VIBe SCALE into clinical practice and surveys degree of anticipated bleeding across common procedures in multiple surgical disciplines.
Methods:
Following online didactic VIBe SCALE training, participating surgeons graded bleeding in ten porcine model videos corresponding to the original validation study. Surgeon and practice information were collected along with percentage of hemostatic product utilization in surgical procedures, the top three surgical procedures performed in their specialty, together with self-reported percentage of bleeding per VIBe SCALE bleeding grade typically encountered in those procedures.
Results:
Using a web-based interface, survey data were collected from 585 participating surgeons; 339 (58%) participants were from academic or university setting, 170 (29%) had >20 years of surgical experience, 217 (37%) performed 11-20 surgeries per month. Overall, 125 (21%) surgeons reported conducting up to 10% minimally invasive surgeries in their practice. Total, 334 (57%) participants considered patient's coagulation status while selecting intraoperative adjunctive hemostatic product, if required; majority (n = 552 [94%]) considered bleeding intensity important when selecting a hemostatic product intraoperatively. Interobserver concordance for VIBe SCALE of 0.89 (perfect concordance = 1.0) as a measure of reproducibility, was achieved.
Conclusions:
This survey strengthens the findings of the earlier validation study and provides human factors verification of the VIBe SCALE as a relevant tool to evaluate and assess bleeding severity across multiple surgical specialties, while demonstrating the useability in contemporary clinical practice and may facilitate hemostatic product choice.
Related Concept Videos
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures II: Colonoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...

