Evaluation of collimated polarized light imaging for real-time intraoperative selective nerve identification in the
K W T K Chin1, A F Engelsman1, P T K Chin2
1Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands.
Abstract:
Intraoperative peripheral nerve lesions are common complications due to misidentification and limitations of surgical nerve identification. This study validates a real-time non-invasive intraoperative method of nerve identification. Long working distance collimated polarized light imaging (CPLi) was used to identify peripheral radial nerve branches in a human cadaver hand by their nerve specific anisotropic optical reflection. Seven ex situ and six in situ samples were examined for nerves, resulting after histological validation, in a 100% positive correct score (CPLi) versus 77% (surgeon). Nerves were visible during a clinical in vivo observation using CPLi. Therefore CPLi is a promising technique for intraoperative nerve identification.