Pre-analytical Errors at the Chemical Pathology Laboratory of a Teaching Hospital
Marlene A Tapper1, James C Pethick2, Lowell L Dilworth3
1Senior Resident, Chemical Pathology, Department of Pathology, Faculty of Medical Sciences, The University of the West Indies, Mona, Kingston 7, Jamaica.
Introduction:
The Chemical Pathology Laboratory at the University Hospital of the West Indies (UHWI) processes specimens received from inpatients, the outpatient department and other medical facilities in Jamaica. Specific rejection criteria are used to determine samples unsuitable for analysis. It has been noted that despite efforts to reduce the number of unacceptable samples received in the laboratory, the problem persists.
Aim:
The study seeks to provide empirical evidence of the inadequacies from which improvements can be formulated.
Materials And Methods:
Errors recorded in the rejection log in the Chemical Pathology laboratory at the University Hospital of the West Indies for the period were assessed. The types and frequency of errors were determined manually. The yearly rejection ratios over a four-year period were evaluated.
Results:
The most common causes for rejection were unlabelled samples (37%), incorrectly labelled specimens (23%), samples submitted in an inappropriate tube (14%) and incomplete or inaccurately completed requisition forms (14%). The rejection ratio for 2015-2016 was 2.1%.
Conclusion:
The laboratory must initiate programmes directed at improving the preanalytical process in order to ensure patient safety.
Related Concept Videos
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Development of Analytical Methods
Data Validation
Key parameters for method validation include:
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...