Related Experiment Video
Updated: Feb 21, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Nasal injury in preterm infants receiving non-invasive respiratory support: a systematic review
Dilini I Imbulana1,2, Brett J Manley1,2,3, Jennifer A Dawson1,2,3
1Newborn Research Centre, The Royal Women's Hospital, Melbourne, Victoria, Australia.
Objective:
Binasal prongs are the most commonly used interface for the delivery of nasal positive airway pressure (CPAP) to preterm infants. However, they are associated with pressure-related nasal injury, which causes pain and discomfort. Nasal injury may necessitate a change in interface and occasionally damage is severe enough to require surgical repair. We aim to determine the incidence and risk factors for nasal injury in preterm infants, and to provide clinicians with strategies to effectively prevent and treat it.
Design:
We conducted a systematic search of databases including MEDLINE (PubMed including the Cochrane Library), EMBASE, CINAHL and Scopus. Included studies enrolled human preterm infants and were published prior to 20 February 2017.
Results:
Forty-five studies were identified, including 14 ra ndomised controlled trials, 10 observational studies, two cohort studies, eight case reports and 11 reviews. The incidence of nasal injury in preterm infants ranged from 20-100%. Infants born <30 weeks' gestation are at highest risk. Strategies shown to reduce nasal injury included: nasal barrier dressings (2 studies, n=244, risk ratio (RD) -0.12, 95%, CI - 0.20 to -0.04), nasal high flow therapy as an alternative to binasal prong CPAP (7 studies, n=1570, risk difference (RD) -0.14, 95% CI -0.17 to -0.10), and nasal masks rather than binasal prongs (5 studies, n=544, RR 0.80, 95% CI 0.64 to 1.00).
Conclusions And Relevance:
Nasal injury is common in preterm infants born <30 weeks' gestational age receiving CPAP via binasal prongs. Larger randomised trials are required to fully evaluate strategies to reduce nasal injury.
More Related Videos
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...