Related Experiment Video
Updated: Feb 21, 2026

Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
Transcranial Doppler Waveforms During Intra-aortic Balloon Pump Counterpulsation for Vasospasm Detection After
Nicholas A Morris1, Nathan Manning2,3,4, Randolph S Marshall5
1Department of Neurology, University of Maryland School of Medicine, Baltimore, Maryland.
Background:
Transcranial Doppler ultrasound is a standard screening tool for vasospasm after subarachnoid hemorrhage. Prevention of vasospasm-induced delayed cerebral ischemia after subarachnoid hemorrhage depends on optimization of cerebral perfusion pressure, which can be challenged by neurogenic stress cardiomyopathy. Intra-aortic balloon pumps have been utilized to augment cerebral perfusion, but they change the transcranial Doppler waveform, altering its interpretability for vasospasm screening.
Objective:
To assess the features of the transcranial Doppler waveform that correlate with vasospasm.
Methods:
We retrospectively reviewed cases of subarachnoid hemorrhage that underwent same-day transcranial Doppler ultrasound and angiography. Transcranial Doppler waveforms were assessed for mean velocity, peak systolic velocity, balloon pump-augmented diastolic velocity, and a novel feature, "delta velocity" (balloon pump-augmented velocity - systolic velocity). Relationship of flow velocity features to vasospasm was estimated by generalized estimating equation models using a Gaussian distribution and an exchangeable correlation structure.
Results:
There were 31 transcranial Doppler and angiography pairings (12 CT angiography/19 digital subtraction angiography) from 4 patients. Fourteen pairings had proximal vasospasm by angiography. Delta velocity was associated with proximal vasospasm (coefficient -6.8 [95% CI -9.8 to -3.8], P < .001). There was no significant correlation with proximal vasospasm for mean velocity (coefficient -13.0 [95% CI -29.3 to 3.4], P = .12), systolic velocity (coefficient -8.7 [95% CI -24.8 to 7.3], P = .29), or balloon pump-augmented velocity (coefficient -15.3 [95% CI -31.3 to 0.71], P = .06).
Conclusion:
Delta velocity, a novel transcranial Doppler flow velocity feature, may reflect vasospasm in patients with subarachnoid hemorrhage and intra-aortic balloon pumps.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...