A Fluorescence Fluctuation Spectroscopy Assay of Protein-Protein Interactions at Cell-Cell Contacts
Published on: December 1, 2018
Fluctuation Scaling, Calibration of Dispersion, and Detection of Differences
Rianne Holland1, Roman Rebmann1, Craig Williams2
1School of Science and Technology, Nottingham Trent University , Clifton Lane, Nottingham NG11 8NS, United Kingdom.
Abstract:
Fluctuation scaling describes the relationship between the mean and standard deviation of a set of measurements. An example is Horwitz scaling, which has been reported from interlaboratory studies. Horwitz and similar studies have reported simple exponential and segmented scaling laws with exponents (α) typically between 0.85 (Horwitz) and 1 when not operating near a detection limit. When approaching a detection limit, the exponents change and approach an apparently Gaussian (α = 0) model. This behavior is often presented as a property of interlaboratory studies, which makes controlled replication to understand the behavior costly to perform. To assess the contribution of instrumentation to larger scale fluctuation scaling, we measured the behavior of two inductively coupled plasma atomic emission spectrometry (ICP-AES) systems, in two laboratories measuring thulium using two emission lines. The standard deviation universally increased with the uncalibrated signal, indicating the system was heteroscedastic. The response from all lines and both instruments was consistent with a single exponential dispersion model having parameters α = 1.09 and β = 0.0035. No evidence of Horwitz scaling was found, and there was no evidence of Poisson noise limiting behavior. The "Gaussian" component was a consequence of background subtraction for all lines and both instruments. The observation of a simple exponential dispersion model in the data allows for the definition of a difference detection limit (DDL) with universal applicability to systems following known dispersion. The DDL is the minimum separation between two points along a dispersion model required to claim they are different according to a particular statistical test. The DDL scales transparently with the mean and works at any location in a response function.
More Related Videos
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Correlation Coefficient