Related Experiment Video
Updated: Feb 21, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Monte Carlo simulation of beta particle-induced bremsstrahlung doses
1University of Novi Sad, Faculty of Sciences, Department of Physics, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia.
None:
It is well known that protection from the external irradiation produced by beta emitters is simpler than the corresponding shielding of radioactive sources that emit gamma radiation. This is caused by the relatively strong absorption (i.e. short range) of electrons in different materials. However, for strong beta sources specific attention should be paid to the bremsstrahlung radiation induced in the source encapsulation (matrix), especially for emitters with relatively high beta-endpoint energy (1 MeV) that are frequently used in nuclear medicine. In the present work, the bremsstrahlung spectra produced in various materials by the following beta emitters, Sr-90 (together with its daughter Y-90), P-32 and Bi-210, were investigated by Monte Carlo simulations using Geant4 software. In these simulations, it is supposed that the point radioactive sources are surrounded by cylindrically shaped capsules made from different materials: Pb, Cu, Al, glass and plastic. For the case of Y-90(Sr-90) in cylindrical lead and aluminum capsules, the dimensions of these capsules have also been varied. The absorbed dose rates from bremsstrahlung radiation were calculated for cases where the encapsulated point source is placed at a distance of 30 mm from the surface of a water cylinder with a mass of 75 kg (approximately representing the human body). The bremsstrahlung dose rate and bremsstrahlung spectrum from the Y-90(Sr-90) point source encapsulated in an Al capsule were also measured experimentally and compared with the corresponding simulation results. In addition, the bremsstrahlung radiation risk for medical staff in therapies using Y-90 was considered in simulations, relating to finger dose as well as whole-body dose during preparation and injection of this radioisotope. The corresponding annual doses were obtained for medical workers for specified numbers of Y-90 applications to patients.
More Related Videos
08:31Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
Published on: June 27, 2022
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Biological Effects of Radiation
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:
Radiation: Applications
The average...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Absorption of Radiation