Sponge Spray-Reaching New Dimensions of Direct Sampling and Analysis by MS
Max Hecht1, Hanno Evard1,2, Kalev Takkis1
1University of Tartu , Institute of Chemistry, 14a Ravila Street, 50411 Tartu, Estonia.
Analytical Chemistry
|October 14, 2017
Summary
Sponge spray enables direct mass spectrometry analysis of clinical samples like blood and urine without extensive preparation. This novel method simplifies and speeds up analysis, allowing for quantitation of substances like penicillin G.
Area of Science:
- Analytical Chemistry
- Clinical Diagnostics
Background:
- Mass spectrometry (MS) analysis of clinical samples often requires extensive and costly sample preparation.
- Simplifying and accelerating this process is crucial for efficient diagnostics.
Purpose of the Study:
- To introduce and evaluate a novel sampling and direct MS analysis approach called sponge spray.
- To demonstrate the feasibility of direct analysis from various biological matrices with minimal sample preparation.
Main Methods:
- Utilized a volumetric absorptive microsampling device for precise sample collection.
- Developed an electrospray method directly from the microsampling device tip for MS analysis.
- Analyzed dried blood, plasma, and urine samples.
Main Results:
- Sponge spray enables direct MS analysis from dried blood, plasma, and urine with no prior sample preparation.
- Quantitation of penicillin G in plasma and urine was demonstrated, despite significant matrix effects.
- The method offers a simplified and faster alternative to traditional sample preparation techniques.
Conclusions:
- Sponge spray is a viable novel approach for direct mass spectrometry analysis of clinical samples.
- This technique significantly reduces sample preparation time and cost.
- Further optimization may overcome matrix effects for broader clinical applications.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...