Related Experiment Video
Updated: Aug 18, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Multivariate optimization of a microextraction by packed sorbent-programmed temperature vaporization-gas
Attilio Naccarato1, Rosangela Elliani2, Giovanni Sindona2
1CNR-Institute of Atmospheric Pollution Research, Division of Rende, UNICAL-Polifunzionale, 87036, Arcavacata di Rende, CS, Italy.
Abstract:
In this work, organophosphate ester flame retardant (OPFRs) assay in environmental waters was addressed by using microextraction by packed sorbent (MEPS) and gas chromatography-tandem mass spectrometry (GC-MS/MS). Ten OPFRs with different physicochemical properties were taken into account as target compounds for a comprehensive method evaluation. Five MEPS cartridges (i.e., C2, C8, C18, Silica, and DVB) and seven solvents (i.e., methanol, ethyl acetate, methyl tert-butyl ether, hexane, acetonitrile, dichloromethane, and trichloromethane) were surveyed. The analysis was performed by using a gas chromatograph equipped with a programmed temperature vaporization injector (PTV). Univariate and multivariate approaches were exploited in order to optimize the parameters affecting the MEPS extraction and the PTV injection of the analytes into the gas chromatographic system. The optimal working conditions were achieved using DVB as sorbent material and acetonitrile as elution solvent. Internal standard calibration was carried out using TBP-d27 and TCEP-d12. Satisfactory values of accuracy and precision were generally obtained as well as limit of detection (2.7-99 pg/mL for tap water; 2.9-97 pg/mL for river water; 3-107 pg/mL for wastewater) and limit of quantification (0.01-0.2 ng/mL). The proposed protocol was evaluated on real case scenarios by analyzing tap water, river water and simulated wastewater samples. The developed method is not only eco-friendly due to the low use of organic solvents but also simple and automatable since the MEPS extraction procedure can be implemented in the autosampler routine. Graphical abstract The steps of the analytical protocol.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

