Effectiveness of enhanced pulse oximetry sonifications for conveying oxygen saturation ranges: a laboratory
E Paterson1, P M Sanderson1,2,3, N A B Paterson3,4
1School of Psychology.
Background:
Anaesthetists monitor auditory information about a patient's vital signs in an environment that can be noisy and while performing other cognitively demanding tasks. It can be difficult to identify oxygen saturation (SpO2) values using existing pulse oximeter auditory displays (sonifications).
Methods:
In a laboratory setting, we compared the ability of non-clinician participants to detect transitions into and out of an SpO2 target range using five different sonifications while they performed a secondary distractor arithmetic task in the presence of background noise. The control sonification was based on the auditory display of current pulse oximeters and comprised a variable pitch with an alarm. The four experimental conditions included an Alarm Only condition, a Variable pitch only condition, and two conditions using sonifications enhanced with additional sound dimensions. Accuracy to detect SpO2 target transitions was the primary outcome.
Results:
We found that participants using the two sonifications enhanced with the additional sound dimensions of tremolo and brightness were significantly more accurate (83 and 96%, respectively) at detecting transitions to and from a target SpO2 range than participants using a pitch only sonification plus alarms (57%) as implemented in current pulse oximeters.
Conclusions:
Enhanced sonifications are more informative than conventional sonification. The implication is that they might allow anaesthetists to judge better when desaturation decreases below, or returns to, a target range.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: