Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Exploring Spatial Distribution of Intrinsic Oxide Trap by Decoupling Channel Thickness Effects in Amorphous IGZO TFTs.

ACS applied materials & interfaces·2026
Same author

Efficient fine-tuning of vision-language adapters in chemical VLMs for molecular image-text tasks.

Journal of cheminformatics·2026
Same author

Theoretical Prediction of Bias in Model-Based Material Decomposition.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same author

Quantitative Enhancement of Spectral Imaging in Photon-Counting CT via Dynamic Energy Thresholding.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same author

High diffuse bone marrow uptake in 18F-FDG PET/CT may reflect the diverse mutational characteristics of multiple myeloma.

The Korean journal of internal medicine·2026
Same author

Mode hopping via nonlinear magnon-magnon coupling in a synthetic antiferromagnet.

Nature communications·2026

Related Experiment Video

Updated: Feb 20, 2026

Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device
14:48

Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device

Published on: April 17, 2021

4.6K

Fully chip-embedded automation of a multi-step lab-on-a-chip process using a modularized timer circuit.

Junsu Kang1, Donghyeon Lee, Young Jin Heo

  • 1Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, 37673, Republic of Korea. wkchung@postech.ac.kr.

Lab on a Chip
|October 21, 2017
PubMed
Summary
This summary is machine-generated.

This study introduces a novel microfluidic process control method using integrated fluidic timer and pneumatic logic circuits. This system enables multi-step liquid handling on-chip without external controllers, advancing microfluidic applications.

More Related Videos

Automated Robotic Liquid Handling Assembly of Modular DNA Devices
11:22

Automated Robotic Liquid Handling Assembly of Modular DNA Devices

Published on: December 1, 2017

13.0K
Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

9.9K

Related Experiment Videos

Last Updated: Feb 20, 2026

Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device
14:48

Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device

Published on: April 17, 2021

4.6K
Automated Robotic Liquid Handling Assembly of Modular DNA Devices
11:22

Automated Robotic Liquid Handling Assembly of Modular DNA Devices

Published on: December 1, 2017

13.0K
Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

9.9K

Area of Science:

  • Microfluidics
  • Biotechnology
  • Automation

Background:

  • Highly-integrated microfluidic systems require precise flow control.
  • Existing actuation devices (pumps, valves) are bulky, limiting system integration.
  • On-chip automation is crucial for complex microfluidic applications.

Purpose of the Study:

  • To develop a microfluidic process control method using built-in circuits.
  • To eliminate the need for external controllers in microfluidic systems.
  • To demonstrate a multi-step droplet treatment automation chip.

Main Methods:

  • Designed a microfluidic circuit comprising a fluidic timer and a pneumatic logic circuit.
  • Utilized modularized timer units for sequential pressure delivery.
  • Implemented a NOR gate array for liquid control.
  • Developed a six-step droplet treatment automation chip.

Main Results:

  • Successfully demonstrated a microfluidic process control method based on integrated circuits.
  • Achieved automated multi-step droplet treatment (loading, separation, reagent injection, incubation, clearing, unloading) on-chip.
  • Confirmed pre-defined step-time execution without external devices.
  • Showcased the scalability of the timer circuit by adding modular units.

Conclusions:

  • The proposed built-in microfluidic circuit enables fully automated, multi-step processes on-chip.
  • This approach overcomes the limitations of bulky external actuation devices.
  • The modular design allows for unlimited extension of process steps, enhancing microfluidic system versatility.