Wide-area measurement system-based supervision of protection schemes with minimum number of phasor measurement units
Swaroop Gajare1, J Ganeswara Rao2, O D Naidu1
1Control Research Area, ABB Corporate Research Center, Bangalore 560048, India.
Abstract:
Cascade tripping of power lines triggered by maloperation of zone-3 relays during stressed system conditions, such as load encroachment, power swing and voltage instability, has led to many catastrophic power failures worldwide, including Indian blackouts in 2012. With the introduction of wide-area measurement systems (WAMS) into the grids, real-time monitoring of transmission network condition is possible. A phasor measurement unit (PMU) sends time-synchronized data to a phasor data concentrator, which can provide a control signal to substation devices. The latency associated with the communication system makes WAMS suitable for a slower form of protection. In this work, a method to identify the faulted line using synchronized data from strategic PMU locations is proposed. Subsequently, a supervisory signal is generated for specific relays in the system for any disturbance or stressed condition. For a given system, an approach to decide the strategic locations for PMU placement is developed, which can be used for determining the minimum number of PMUs required for application of the method. The accuracy of the scheme is tested for faults during normal and stressed conditions in a New England 39-bus system simulated using EMTDC/PSCAD software. With such a strategy, maloperation of relays can be averted in many situations and thereby blackouts/large-scale disturbances can be prevented.This article is part of the themed issue 'Energy management: flexibility, risk and optimization'.
Related Concept Videos
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Pilot and Numeric Relaying
Kirchoff's Laws using Phasors
Kirchhoff's voltage law (KVL) states that the sum of phasor voltages around a closed loop in an AC circuit equals zero....
Phasors
One of the significant benefits of using phasors is that they simplify the analysis of AC circuits by eliminating the time dependence of the current and voltage. This transformation...