Wide-area measurement system-based supervision of protection schemes with minimum number of phasor measurement units

Swaroop Gajare1, J Ganeswara Rao2, O D Naidu1

  • 1Control Research Area, ABB Corporate Research Center, Bangalore 560048, India.

Related Concept Videos

Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
844
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
467
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
450
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
499
Kirchoff's Laws using Phasors01:12

Kirchoff's Laws using Phasors

Analyzing AC circuits in electrical systems is a fundamental aspect of electrical engineering. In these circuits, AC power is supplied from a distribution panel and wired to various household appliances in parallel. To perform a comprehensive analysis, electrical engineers use Kirchhoff's voltage and current laws, which are equally applicable in AC circuits as in DC circuits.
Kirchhoff's voltage law (KVL) states that the sum of phasor voltages around a closed loop in an AC circuit equals zero....
876
Phasors01:12

Phasors

Phasors are a powerful mathematical tool used to analyze alternating current (AC) circuits. They provide a complex number representation of sinusoids, with the magnitude of the phasor equating to the amplitude of the sinusoid and the angle of the phasor representing the phase measured from the positive x-axis.
One of the significant benefits of using phasors is that they simplify the analysis of AC circuits by eliminating the time dependence of the current and voltage. This transformation...
1.3K