Pulse oximetry in the neck - a proof of concept
Abstract:
Oxygen saturation levels are routinely monitored in clinical settings. Pulse oximetry, in transmittance operation mode, is the most common method of estimating oxygen saturation (SpO2). This is inexpensive and non-invasive and thus allows for long-term monitoring. However, it suffers from issues such as signal integrity, reliability and patient comfortability. As a result, there is an interest in exploring other locations on the body where oxygen saturation can be measured reliably. In this paper, a wearable device has been designed to study the feasibility of extracting photoplethysmogram (PPG) signals at the neck in reflectance pulse oximetry mode. It explores the signal integrity and strength compared to other locations as well as the presence of motion artefacts in that location. The results demonstrate that the PPG signals acquired at the neck show a very strong correlation (r=0.82) with the SpO2 values obtained using a commercial device. Further, the SpO2 values are calculated with an accuracy of 98.6%.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation